<?xml version="1.0" encoding="UTF-8"?>
<record>
  <leader>     cx  r22     2  45  </leader>
  <controlfield tag="001">204954878</controlfield>
  <controlfield tag="003">http://www.idref.fr/204954878</controlfield>
  <controlfield tag="004">20171020</controlfield>
  <controlfield tag="005">20250419014956.000</controlfield>
  <controlfield tag="006">0499</controlfield>
  <controlfield tag="007">0499</controlfield>
  <controlfield tag="008">Tr2</controlfield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">20171020afrey50      ba0</subfield>
  </datafield>
  <datafield tag="101" ind1=" " ind2=" ">
    <subfield code="a">fre</subfield>
    <subfield code="2">639-2</subfield>
  </datafield>
  <datafield tag="103" ind1=" " ind2=" ">
    <subfield code="a"> 1991     </subfield>
  </datafield>
  <datafield tag="104" ind1=" " ind2=" ">
    <subfield code="a">k</subfield>
    <subfield code="f">fre</subfield>
  </datafield>
  <datafield tag="106" ind1=" " ind2=" ">
    <subfield code="a">0</subfield>
    <subfield code="b">#</subfield>
    <subfield code="c">#</subfield>
  </datafield>
  <datafield tag="152" ind1=" " ind2=" ">
    <subfield code="a">AFNOR</subfield>
  </datafield>
  <datafield tag="189" ind1=" " ind2=" ">
    <subfield code="a">Oeuvre Textuelle</subfield>
  </datafield>
  <datafield tag="241" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0</subfield>
    <subfield code="t">Préparation de couches minces d&apos;oxynitrure de silicium par PECVD en vue de greffage chimique, Application à un ISFET PH </subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0y</subfield>
    <subfield code="a">Le premier objectif de cette thèse est de déposer sur de la silice thermique une fine couche d&apos;oxynitrure de silicium (sio#xn#yh#z préparée par pecvd (plasma enhanced chemical vapor deposition). Cette membrane doit être à la fois sensible aux protons et facilement modifiable par greffage chimique. De plus, elle devrait être une bonne barrière de diffusion. Il est possible de contrôler le nombre de sites de surfaces (si#2nh, sinh#2, sih) en faisant varier le débit des gaz utilisés lors de dépôt (sih#4, nh#3, n#2o) et de le vérifier par spectroscopie ir. La réponse au ph de la structure si/sio#2/sio#1#,#6#4n#0#,#4#1h#0#;#4#9 a été déterminée par des mesures c(v): 60 mv/ph. Apres un greffage chimique sur les sites sinh/nh#2 de longues chaines alkyles (c18) pour rendre la membrane insensible aux protons, la réponse au ph n&apos;est plus que de 15 mv/ph. De plus une méthode d&apos;impédance électrochimique a été proposée permettant de suivre la qualité de l&apos;encapsulation des isfets. Nous avons travaillé en mode potentiostatique en superposant une tension sinusoïdale à fréquence variable. Avant le disfonctionnement des isfets, trois étapes ont pu être observées.</subfield>
  </datafield>
  <datafield tag="328" ind1=" " ind2="0">
    <subfield code="b">Thèse de doctorat</subfield>
    <subfield code="c">Électronique</subfield>
    <subfield code="e">Ecully, Ecole centrale de Lyon</subfield>
    <subfield code="d">1991</subfield>
  </datafield>
  <datafield tag="441" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0</subfield>
    <subfield code="t">Study of PECVD Silicon Oxynitride thin layers as isfet and refet memranes for PH detection</subfield>
  </datafield>
  <datafield tag="501" ind1=" " ind2="1">
    <subfield code="3">071524169</subfield>
    <subfield code="7">ba0yba04</subfield>
    <subfield code="a">Chovelon</subfield>
    <subfield code="b">Jean-Marc</subfield>
    <subfield code="f">1962-....</subfield>
    <subfield code="4">070</subfield>
  </datafield>
  <datafield tag="501" ind1=" " ind2="1">
    <subfield code="3">067830439</subfield>
    <subfield code="7">ba0yba04</subfield>
    <subfield code="a">Jaffrezic-Renault</subfield>
    <subfield code="b">Nicole</subfield>
    <subfield code="f">19..-....</subfield>
    <subfield code="4">727</subfield>
  </datafield>
  <datafield tag="511" ind1="0" ind2="2">
    <subfield code="3">033894221</subfield>
    <subfield code="7">ba0yba04</subfield>
    <subfield code="a">École Centrale de Lyon</subfield>
    <subfield code="c">1857-....</subfield>
    <subfield code="4">295</subfield>
  </datafield>
  <datafield tag="511" ind1="0" ind2="2">
    <subfield code="3">088209423</subfield>
    <subfield code="7">ba0yba04</subfield>
    <subfield code="a">Laboratoire de physique chimie des interfaces</subfield>
    <subfield code="c">Ecully, Rhône</subfield>
    <subfield code="4">981</subfield>
  </datafield>
  <datafield tag="606" ind1="1" ind2=" ">
    <subfield code="3">027222004</subfield>
    <subfield code="a">Capteurs (technologie)</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="606" ind1="1" ind2=" ">
    <subfield code="3">032989873</subfield>
    <subfield code="a">Nitrure de silicium</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="606" ind1="1" ind2=" ">
    <subfield code="3">02786992X</subfield>
    <subfield code="a">Électrodes sélectives d&apos;ions</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="606" ind1="1" ind2=" ">
    <subfield code="3">027282295</subfield>
    <subfield code="a">Couches minces</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="608" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0</subfield>
    <subfield code="3">027253139</subfield>
    <subfield code="a">Thèses et écrits académiques</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="610" ind1="1" ind2=" ">
    <subfield code="a">ISFET</subfield>
    <subfield code="a">Oxynitrure de silicium</subfield>
    <subfield code="a">PECVD</subfield>
    <subfield code="a">Sensibilité en PH</subfield>
    <subfield code="a">Greffage chimique</subfield>
  </datafield>
  <datafield tag="686" ind1=" " ind2=" ">
    <subfield code="a">530</subfield>
    <subfield code="2">TEF</subfield>
  </datafield>
  <datafield tag="686" ind1=" " ind2=" ">
    <subfield code="a">620</subfield>
    <subfield code="2">TEF</subfield>
  </datafield>
  <datafield tag="801" ind1=" " ind2="3">
    <subfield code="a">FR</subfield>
    <subfield code="b">Abes</subfield>
    <subfield code="c">20250419</subfield>
    <subfield code="g">AFNOR</subfield>
  </datafield>
</record>

