cx r22 2 45
211328049
http://www.idref.fr/211328049
20171021
20220523012204.000
0499
0499
Tr2
20171021afrey50 ba0
fre
1999
fre
0
#
#
AFNOR
Oeuvre Textuelle
ba0yba0
CONTRIBUTION AU DEVELOPPEMENT ET APPLICATIONS D'UNE METHODOLOGIE POUR LA CONCEPTION DE REGULATEURS LINEAIRES INVARIANTS
ba0yba0y
CE DOCUMENT SE VEUT UN GUIDE METHODOLOGIQUE DESTINE A FACILITER LA CONCEPTION DE REGULATEURS LINEAIRES INVARIANTS. DEUX METHODES SONT PROPOSEES, LE PLACEMENT DE POLES ROBUSTE ET LE CONTROLE D'ETAT STANDARD. LA PREMIERE EST EXCLUSIVEMENT RESERVEE A LA RESOLUTION DE PROBLEMES DE COMMANDE MONOVARIABLES, ALORS QUE LA DEUXIEME PEUT TRAITER LE CAS MULTIVARIABLE. LES DEUX METHODES PROPOSENT UNE MEME STRATEGIE DE REGLAGE DES COMPROMIS PERFORMANCES / ROBUSTESSE / SENSIBILITE AU BRUIT, VIA DES PARAMETRES DE SYNTHESE DE HAUT NIVEAU IDENTIQUE. LES PROPRIETES DE ROBUSTESSE DE CHACUNE DES DEUX METHODES REPOSENT SUR UN DOUBLE EFFET LTR, QUI PERMET DE RESTAURER A LA FOIS LES MARGES DE GAIN ET PHASE ET LA MARGE DE RETARD, SOUS CONDITION DE MINIMUM DE PHASE ET DE NON INSTABILITE EXPONENTIELLE. LA PRESENTATION THEORIQUE EST ACCOMPAGNEE D'EXEMPLES. POUR CHACUN D'ENTRE EUX SONT PRESENTES LE CAHIER DES CHARGES, LA DEMARCHE METHODOLOGIQUE ADOPTEE, LES REGLAGES ET LES RESULTATS OBTENUS. DEUX APPLICATIONS SIGNIFICATIVES ONT ETE TRAITEES AVEC LE CONTROLE D'ETAT STANDARD. IL S'AGIT DU REJET DE L'HARMONIQUE 5 DANS LE CADRE DE LA DEPOLLUTION DU RESEAU ELECTRIQUE MOYENNE TENSION, ET DE LA CONDUITE D'UNE CENTRALE THERMIQUE AU CHARBON. L'ORIGINALITE DE LA PREMIERE APPLICATION RESIDE DANS LA CARACTERISTIQUE DE LA PERTURBATION A COMPENSER, QUI EST SINUSOIDALE. LA PARTICULARITE DE LA DEUXIEME EST SON CARACTERE MULTIVARIABLE, PUISQUE TROIS GRANDEURS SONT A CONTROLER SIMULTANEMENT.
Thèse de doctorat
Sciences et techniques
Nantes
1999
ba0yba05
PUREN
SOPHIE
070
ba0yba0
027253139
Thèses et écrits académiques
rameau
SCIENCES ET TECHNIQUES : INFORMATIQUE. AUTOMATIQUE THEORIQUE. SYSTEMES
SCIENCES ET TECHNIQUES : GENIE CHIMIQUE
SYNTHESE COMMANDE ; COMMANDE LINEAIRE ; INVARIANT ; ASSIGNATION POLE ; COMMANDE ROBUSTE ; RESTITUTION TRANSFERT BOUCLE ; RESEAU ELECTRIQUE ; COMMANDE PROCESSUS ; CENTRALE THERMIQUE ; COMMANDE ETAT STANDARD
600
TEF
500
TEF
FR
Abes
20220523