<?xml version="1.0" encoding="UTF-8"?>
<record>
  <leader>     cx  r22     2  45  </leader>
  <controlfield tag="001">212768662</controlfield>
  <controlfield tag="003">http://www.idref.fr/212768662</controlfield>
  <controlfield tag="004">20171021</controlfield>
  <controlfield tag="005">20241121013011.000</controlfield>
  <controlfield tag="006">0499</controlfield>
  <controlfield tag="007">0499</controlfield>
  <controlfield tag="008">Tr2</controlfield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">20171021afrey50      ba0</subfield>
  </datafield>
  <datafield tag="101" ind1=" " ind2=" ">
    <subfield code="a">fre</subfield>
    <subfield code="2">639-2</subfield>
  </datafield>
  <datafield tag="103" ind1=" " ind2=" ">
    <subfield code="a"> 1991     </subfield>
  </datafield>
  <datafield tag="104" ind1=" " ind2=" ">
    <subfield code="a">k</subfield>
    <subfield code="f">fre</subfield>
  </datafield>
  <datafield tag="106" ind1=" " ind2=" ">
    <subfield code="a">0</subfield>
    <subfield code="b">#</subfield>
    <subfield code="c">#</subfield>
  </datafield>
  <datafield tag="152" ind1=" " ind2=" ">
    <subfield code="a">AFNOR</subfield>
  </datafield>
  <datafield tag="189" ind1=" " ind2=" ">
    <subfield code="a">Oeuvre Textuelle</subfield>
  </datafield>
  <datafield tag="241" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0</subfield>
    <subfield code="t">Elaboration et conception d&apos;un système d&apos;acquisition multivoie pour la tomographie d&apos;impédance électrique</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0y</subfield>
    <subfield code="a">LA TOMOGRAPHIE D&apos;IMPEDANCE ELECTRIQUE (T.I.E.) EST UNE RECENTE METHODE D&apos;IMAGERIE MEDICALE. ELLE A POUR BUT DE VISUALISER LA DISTRIBUTION DE RESISTIVITE A L&apos;INTERIEUR D&apos;UN MILIEU, LE TISSU MAMMAIRE DANS NOTRE APPLICATION. POUR CELA, ON INJECTE DANS CE MILIEU UN COURANT ALTERNATIF PAR L&apos;INTERMEDIAIRE D&apos;ELECTRODES DITES D&apos;APPORT. LES DIFFERENCES DE POTENTIELS ENGENDREES PAR LE PASSAGE DE CE COURANT SONT MESUREES EN SURFACE GRACE A DES VOLTMETRES DIFFERENTIELS RELIES A DES ELECTRODES DITES DE MESURE. LA RESOLUTION FINALE DEPEND DU NOMBRE DE MESURES. L&apos;IMPEDANCE ELECTRIQUE DES TISSUS BIOLOGIQUES VARIE SUIVANT LA FREQUENCE DU SIGNAL INJECTE. LE MODULE ET LA PHASE DE L&apos;IMPEDANCE D&apos;UN TISSU DEPENDENT DE SA STRUCTURE, DE SA NATURE ET DE SON ETAT PHYSIOPATHOLOGIQUE. DES MODIFICATIONS CELLULAIRES, COMME CELLES QUI SURVIENNENT EN PRESENCE D&apos;UN CANCER, MODIFIENT LA REPONSE HARMONIQUE D&apos;UN TISSU. EN ETABLISSANT LA CARTOGRAPHIE D&apos;IMPEDANCE MULTI-FREQUENTIELLE D&apos;UN TISSU, ON ESPERE AINSI DETECTER LES HETEROGENEITES LOCALISEES SUR DES ZONES CANCEREUSES. LES CONDITIONS D&apos;APPORT (IMPEDANCES D&apos;ELECTRODES ELEVEES) ET DE MESURE (SIGNAUX TRES FAIBLES, TENSION DE MODE COMMUN ELEVE) ENGENDRENT UN CAHIER DES CHARGES CONTRAIGNANT ET L&apos;OBLIGATION DE TRAVAILLER AUX LIMITES TECHNOLOGIQUES DES COMPOSANTS. LE TRAVAIL PRESENTE A CONSISTE EN L&apos;ELABORATION ET LA CONCEPTION D&apos;UN SYSTEME D&apos;ACQUISITION MULTIVOIES PERMETTANT D&apos;INJECTER UN COURANT SINUSOIDAL SUR UNE LARGE GAMME DE FREQUENCE, DE MESURER EN SURFACE 32 DIFFERENCES DE POTENTIELS, DE PREPARER ET CONVERTIR CES DONNEES QUI SERONT ENSUITE TRAITEES PAR UN MICRO-ORDINATEUR. LES RESULTATS OBTENUS IN-VITRO ET IN-VIVO CONFIRMENT LA FAISABILITE DE LA TOMOGRAPHIE D&apos;IMPEDANCE ELECTRIQUE</subfield>
  </datafield>
  <datafield tag="328" ind1=" " ind2="0">
    <subfield code="b">Thèse de doctorat</subfield>
    <subfield code="c">Sciences. Systèmes électroniques</subfield>
    <subfield code="e">Lyon 1</subfield>
    <subfield code="d">1991</subfield>
  </datafield>
  <datafield tag="441" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0</subfield>
    <subfield code="t">DESIGN AND DEVELOPMENT OF AN ACQUISITION SYSTEM FOR ELECTRICAL IMPEDANCE TOMOGRAPHY</subfield>
  </datafield>
  <datafield tag="501" ind1=" " ind2="1">
    <subfield code="3">026692937</subfield>
    <subfield code="7">ba0yba04</subfield>
    <subfield code="a">Asch</subfield>
    <subfield code="b">Georges</subfield>
    <subfield code="4">727</subfield>
    <subfield code="4">956</subfield>
  </datafield>
  <datafield tag="501" ind1=" " ind2="1">
    <subfield code="3">185752993</subfield>
    <subfield code="7">ba0yba04</subfield>
    <subfield code="a">Trillaud</subfield>
    <subfield code="b">Christian</subfield>
    <subfield code="f">1962-....</subfield>
    <subfield code="4">070</subfield>
  </datafield>
  <datafield tag="511" ind1="0" ind2="2">
    <subfield code="3">026402823</subfield>
    <subfield code="7">ba0yba04</subfield>
    <subfield code="a">Université Claude Bernard</subfield>
    <subfield code="c">Lyon</subfield>
    <subfield code="c">1971-....</subfield>
    <subfield code="4">295</subfield>
  </datafield>
  <datafield tag="606" ind1=" " ind2=" ">
    <subfield code="3">078485932</subfield>
    <subfield code="a">Impédance bioélectrique</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="606" ind1=" " ind2=" ">
    <subfield code="3">035570814</subfield>
    <subfield code="a">Imagerie médicale</subfield>
    <subfield code="x">Appareils et matériel</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="606" ind1=" " ind2=" ">
    <subfield code="3">02725416X</subfield>
    <subfield code="a">Tissus (histologie)</subfield>
    <subfield code="3">027976785</subfield>
    <subfield code="x">Propriétés électriques</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="608" ind1=" " ind2=" ">
    <subfield code="7">ba0yba0</subfield>
    <subfield code="3">027253139</subfield>
    <subfield code="a">Thèses et écrits académiques</subfield>
    <subfield code="2">rameau</subfield>
  </datafield>
  <datafield tag="610" ind1="1" ind2=" ">
    <subfield code="a">SCIENCES MEDICALES : TECHNIQUES D&apos;EXPLORATION ET DE DIAGNOSTIC</subfield>
  </datafield>
  <datafield tag="610" ind1="2" ind2=" ">
    <subfield code="a">IMPEDANCE BIOELECTRIQUE/GENERATEUR DE COURANT/AMPLIFICATEUR D&apos;INSTRUMENTATION/ELECTRODES DE SURFACE</subfield>
  </datafield>
  <datafield tag="686" ind1=" " ind2=" ">
    <subfield code="a">610</subfield>
    <subfield code="2">TEF</subfield>
  </datafield>
  <datafield tag="801" ind1=" " ind2="3">
    <subfield code="a">FR</subfield>
    <subfield code="b">Abes</subfield>
    <subfield code="c">20241121</subfield>
    <subfield code="g">AFNOR</subfield>
  </datafield>
</record>

