{"record":{"leader":"cx  r22     2  45","datafield":[{"ind2":" ","ind1":" ","subfield":{"code":"a","content":"20220505afrey50      ba0"},"tag":100},{"ind2":" ","ind1":" ","subfield":[{"code":"a","content":"fre"},{"code":2,"content":"639-2"}],"tag":101},{"ind2":" ","ind1":" ","subfield":{"code":"a","content":2019},"tag":103},{"ind2":" ","ind1":" ","subfield":[{"code":"a","content":"k"},{"code":"f","content":"fre"}],"tag":104},{"ind2":" ","ind1":" ","subfield":[{"code":"a","content":0},{"code":"b","content":"#"},{"code":"c","content":"#"}],"tag":106},{"ind2":" ","ind1":" ","subfield":{"code":"a","content":"AFNOR"},"tag":152},{"ind2":" ","ind1":" ","subfield":{"code":"a","content":"Oeuvre Textuelle"},"tag":189},{"ind2":" ","ind1":" ","subfield":[{"code":7,"content":"ba0yba0"},{"code":"t","content":"Etude d' interactions contenant-contenu lors de la perfusion de bevacizumab via une chambre implantable"}],"tag":241},{"ind2":" ","ind1":" ","subfield":[{"code":7,"content":"ba0yba0y"},{"code":"a","content":"Dans un montage de perfusion, de nombreux dispositifs médicaux sont composés de polymères et sont à risque d\u2019interactions avec les médicaments administrés. L\u2019objectif de ce travail était d\u2019évaluer les interactions contenant-contenu lors de la perfusion de bevacizumab à travers des chambres implantables. La perfusion a été simulée sur un montage complet comprenant une poche, un perfuseur en PVC, une aiguille de Huber et une chambre implantable équipée d\u2019un cathéter en silicone ou en polyuréthane (PU). L\u2019analyse de la stabilité physicochimique du médicament de nature protéique au cours de la perfusion a été réalisée par : examen visuel, comptage des particules subvisibles, spectroscopie à corrélation de photons, chromatographie d\u2019exclusion stérique et chromatographie échangeuse d\u2019ions. Les propriétés mécaniques des cathéters ont été évaluées par mesure de la dureté Shore A, de l\u2019élongation et contrainte à rupture et du module d\u2019Young. Les propriétés physicochimiques de la surface interne des cathéters ont été analysées par spectroscopie FTIR en mode ATR, microscopie électronique à balayage (MEB) et mesure de l\u2019angle de contact. Aucune des analyses n\u2019a mis en évidence de perte ou d\u2019instabilité du bevacizumab lors de la perfusion. Après une perfusion, les propriétés mécaniques des cathéters ont été conservées et une diminution de l\u2019angle de contact a été observée (plus importante pour les cathéters en PU que pour ceux en silicone). Une modification de l\u2019état de surface a également été mise en évidence par MEB. Ces modifications pourraient être dues à un phénomène de sorption du bevacizumab sur le cathéter ou de relargage d\u2019un additif entrant dans la composition du polymère."}],"tag":300},{"ind2":0,"ind1":" ","subfield":[{"code":"b","content":"Thèse d'exercice"},{"code":"c","content":"Pharmacie"},{"code":"e","content":"Université Clermont Auvergne (2017-2020)"},{"code":"d","content":2019}],"tag":328},{"ind2":1,"ind1":" ","subfield":[{"code":3,"content":248852272},{"code":7,"content":"ba0yba06"},{"code":"a","content":"Tokhadzé"},{"code":"b","content":"Nicolas"},{"code":"f","content":"1990-...."},{"code":4,"content":"070"}],"tag":501},{"ind2":1,"ind1":" ","subfield":[{"code":3,"content":"077271939"},{"code":7,"content":"ba0yba06"},{"code":"a","content":"Sautou"},{"code":"b","content":"Valérie"},{"code":4,"content":727}],"tag":501},{"ind2":2,"ind1":0,"subfield":[{"code":3,"content":196200032},{"code":7,"content":"ba0yba06"},{"code":"a","content":"Université Clermont Auvergne"},{"code":"c","content":"2017-2020"},{"code":4,"content":295}],"tag":511},{"ind2":" ","ind1":" ","subfield":[{"code":3,"content":"027880966"},{"code":"a","content":"Anticorps monoclonaux"},{"code":2,"content":"rameau"}],"tag":606},{"ind2":" ","ind1":" ","subfield":[{"code":3,"content":"061610941"},{"code":"a","content":"Chambres à cathéter implantables"},{"code":2,"content":"rameau"}],"tag":606},{"ind2":" ","ind1":" ","subfield":[{"code":3,"content":"027743594"},{"code":"a","content":"Perfusion"},{"code":2,"content":"rameau"}],"tag":606},{"ind2":" ","ind1":" ","subfield":[{"code":7,"content":"ba0yba0"},{"code":3,"content":"027253139"},{"code":"a","content":"Thèses et écrits académiques"},{"code":2,"content":"rameau"}],"tag":608},{"ind2":3,"ind1":" ","subfield":[{"code":"a","content":"FR"},{"code":"b","content":"Abes"},{"code":"c","content":20220624},{"code":"g","content":"AFNOR"}],"tag":801}],"controlfield":[{"tag":"001","content":262205610},{"tag":"003","content":"http://www.idref.fr/262205610"},{"tag":"004","content":20220505},{"tag":"005","content":20220624013934},{"tag":"006","content":"0499"},{"tag":"007","content":"0499"},{"tag":"008","content":"Tr2"}]}}
